Prosthodontics & Occlusion · single question

Which pontic design is WORST for oral hygiene?

  1. Modified ridge-lap
  2. Conical (bullet) pontic
  3. Sanitary/hygienic pontic
  4. Saddle (ridge-lap) pontic
Show answer and explanation

Correct answer: D. Saddle (ridge-lap) pontic

  • A. Incorrect – contacts only the facial; cleansable lingually.
  • B. Incorrect. A conical pontic has minimal tissue contact and is relatively cleansable; the saddle/ridge-lap pontic overlaps the ridge on both sides and is the least hygienic.
  • C. Incorrect – this design is specifically the most cleansable (no tissue contact).
  • D. Correct – it overlaps both facial and lingual of the ridge with a large concave tissue contact that cannot be cleaned; it is the least hygienic and is contraindicated.

Practice Prosthodontics & Occlusion questions Prosthodontics & Occlusion study notes