Prosthodontics & Occlusion · single question

What caused the mobility and bone loss around the tooth with the precision attachment?

  1. Distal torque forces generated by the attachment connecting to the RPD
  2. Primary occlusal trauma
  3. Periodontitis alone
  4. Pulpal necrosis
Show answer and explanation

Correct answer: A. Distal torque forces generated by the attachment connecting to the RPD

Distal torque forces generated by the attachment In a distal-extension RPD with a rigid attachment, the denture base fulcrums around the abutment during function; the lever action transmits distal torquing forces to the abutment, causing progressive bone loss and mobility. Stress breakers and splinting adjacent teeth help reduce this effect.