Prosthodontics & Occlusion · single question
A maxillary complete denture repeatedly loses its peripheral (border) seal and dislodges when the patient opens wide or moves the mandible. Which fault is MOST likely responsible?
Show answer and explanation
Correct answer: C. An over-thick or over-extended distobuccal flange contacting the coronoid process
- A. An under-extended labial flange reduces retention passively and continuously; it does not produce the characteristic dislodgement tied to mandibular MOVEMENT.
- B. Relief over the incisive papilla prevents pressure on the nasopalatine neurovascular bundle. Excessive relief there might allow slight rocking but does not break the peripheral seal on opening.
- C. CORRECT. The distobuccal flange occupies the ZYGOMATIC-ALVEOLAR (coronoid) space. When the mandible opens or moves laterally, the CORONOID PROCESS of the mandible sweeps forward and medially into this region. A flange that is too thick or too long there is struck by the coronoid, which lifts the denture and breaks the border seal — the patient reports the upper denture dropping specifically on wide opening or chewing. The correction is to thin and reduce the distobuccal flange, not to add more material.
- D. A seal placed anterior to the vibrating line would be positioned on immovable tissue — an error, but one causing a persistent leak rather than movement-dependent dislodgement.
Note: Sort denture complaints by TIMING. Constant looseness = border extension or seal problems. Looseness only on FUNCTION = interference with a moving structure: coronoid at the distobuccal flange, buccal frenum, mylohyoid ridge or masseter groove in the lower denture.
Practice Prosthodontics & Occlusion questions Prosthodontics & Occlusion study notes